Candela – SI Unit of Measurement

By MathHelloKitty

If you happen to be viewing the article Candela – SI Unit of Measurement? on the website Math Hello Kitty, there are a couple of convenient ways for you to navigate through the content. You have the option to simply scroll down and leisurely read each section at your own pace. Alternatively, if you’re in a rush or looking for specific information, you can swiftly click on the table of contents provided. This will instantly direct you to the exact section that contains the information you need most urgently.

Vision is one of the most important senses that allow humans to interact and perceive the world. Vision detects light from the surroundings to gain information about the environment around oneself. Candela is the SI unit used to measure the visual intensity of a light source (luminous intensity). This is a unique SI unit, which is highly dependent on human perception.  

The Candela is the SI unit for photometry and should not be confused with the total light emitted by an object, which is given by lumen. Candela merely represents the amount of light perceived by the human visual system. 

Origin of Candela

Candela Latin word ‘Candle’ is a word that refers to an ancient light source, still in use today. Before 1948, there was no standard measuring system for luminous intensity around the world. The luminosity measure was based on the brightness of a candle/ incandescent lamp of certain composition or design respectively. 

READ  Fraunhofer Lines - Detailed Explanation and FAQs

Back then, Candlepower was used to define luminous intensity depending on the candle. The English standard of candlepower was defined as the light produced by a pure spermaceti candle weighing 1/6th pound with a burning rate of 120 grains per hour whereas countries like Germany, Scandinavia, and Austria use the Hefner lamp as a luminous object. 

The candela was first defined by French Physicist and inventor, Jules Violle. He launched a unit called Violle, which is the light emitted by 1cm2 of platinum at its melting or freezing point. This intensity of emitted light was caused by Plank radiation (due to the black body effect) and thus eliminated the dependency of the unit on the construction of the device. This also made it easy to measure the quantity as the device was easy to manufacture and high-quality platinum was readily available back then. 

Definition of Candela

In 2018, the 26th general conference on weights and measures redefined candela, which came into effect from 20th May 2019, defined one candela as the luminous intensity in a given direction produced by monochromatic radiation of frequency  540 × 1012 Hz and has an intensity of 1/683 watts per steradian.  

The frequency of around 555nm is chosen because the human eye is most sensitive towards this frequency under bright conditions. In this condition, photopic vision prevails over scotopic vision. 

Candela Expression

One candela is mathematically expressed as: 

1cd= (\[\frac{Kcd}{683}\]) Kgm2 s-3 sr-1

The unit is dependent on Luminous intensity and radiant intensity for a given wavelength of light. A common candle emits candela power 1 cd of luminosity on average. Luminance is measured in Lux, which is defined as one candela per square metre. It is also called nits in some cases. 

READ  The Eclipse - Wonders of our Solar System

[Image will be Uploaded Soon]

Figure: Graph of Photopic Luminous Intensity

Other Measures of Light

Lumen is also a measure of light intensity. Lumen defined the total luminous flux of a light-emitting body by multiplying the angular span of the emitted light with intensity (expressed in candela) If we take an example of an LED, the total light energy produced by different types of LED is almost the same, but the apex angle of emission varies. The LED, which emits at a narrow-angle, will have greater intensity, than the same energy emitted over a broader angle. 

Lux is the measure of luminance on a surface. Lux is expressed in units of candela per square meter. On a sphere of radius 1 meter, one steradian represents an area of 1 m2. Thus as a distance of 1 meter, one candela is equal to the values for lux. 

Foot Candela

Foot-candle is a unit of illuminance/ light intensity, which is not recognized as a SI unit. One foot-candle is defined as one lumen per square foot. If a point source of light of 1 candela is placed in the centre of a sphere of 1-foot radius, then the illumination on the inside surface of the sphere is 1 unit of foot-candle. One foot-candle is about 10.76 lux. A foot-candle is a common unit of measurement around the world In the architectural industry to map and plan spatial lighting systems. It is also essential for monitoring lighting in places like museums and galleries where there may be photosensitive objects. It is also required in the maintenance of greenhouse or artificial plant culture environments as light intensity is a major factor in the rate of photosynthesis in plants. 

READ  To Find the Surface Tension of Water by Capillary Rise Method

Did You Know?

  • The candela is the one and only SI base unit used to quantify our perception of a piece of objective physical reality. 

  • The sun is one of the brightest objects we see in our daily life. It has been found that illuminance due to the sun on earth is about 133000 lux. Upon conversion to candlepower, the luminous intensity of the sun becomes equivalent to 3.0 x1027 or 3 octillion candles. 

So, that is all about Candela, an important unit and that has immense significance in the world of science. 

Thank you so much for taking the time to read the article titled Candela – SI Unit of Measurement written by Math Hello Kitty. Your support means a lot to us! We are glad that you found this article useful. If you have any feedback or thoughts, we would love to hear from you. Don’t forget to leave a comment and review on our website to help introduce it to others. Once again, we sincerely appreciate your support and thank you for being a valued reader!

Source: Math Hello Kitty
Categories: Physics